How To Specify A Switch

A Comprehensive Guide to Selecting the Right Pressure Switch

Understanding the Pressure Switch

Pressure switches fulfill an amazing variety of monitoring and control applications across virtually every industry, from appliances to supercomputers. Whether monitoring airflow in a heating system or controlling gas pressure in a water heater, these "silent sentinels" provide essential safety and functionality to machine designs.

Definition A Pressure Switch is a mechanical device that converts a pressure change (pressure, vacuum, or differential) into an electrical function using a pressure-responsive sensor coupled to a switching mechanism.

Common Sensor Types

Diaphragm-Actuated

Utilizes a flexible silicone membrane. High surface area allows for conversion of small pressure/vacuum amounts into enough force for snap-action switching.

Piston-Actuated

Uses a robust metal piston. Ideal for high-pressure applications or hostile media where durability is paramount.

Flex Circuit Diaphragm

A small metal diaphragm etched from circuit board layers. Designed for very high frequency opening and closing over long duty cycles.

Step 1: Electrical Requirements

Developing your specification proceeds naturally from your requirements for guarding or switching a particular circuit. Ask yourself:

Voltage?
Current Load?
AC or DC?
Inductive or Resistive?

For low-energy circuits (below 20mA), a Leaf Switch may suffice. Higher current applications typically require a Snap-Action Switch or a Switch-Triac combination to handle higher loads while preserving accuracy.

Step 2: Mechanical Differential (Deadband)

Engineers use mechanical differential to enhance safety and prevent "nuisance tripping."

  • Actuation Point: The pressure at which the switch trips.
  • Reset Point: The point where the mechanism returns to its normal position.
  • Hysteresis (Deadband): The gap between trip and reset. Snap-action switches provide higher reliability but have a larger characteristic deadband than leaf switches.

Step 3: Media & Environment

The fluid medium being sensed determines the necessary diaphragm material:

Media Type Recommended Material
Fuel Vapors Fluorosilicone
Food / Medical EPDM
Standard Air/Gas Silicone, Polyurethane, BUNA, VITON

* For hot, dirty, or hostile media, a piston sensor isolated behind a non-magnetic barrier may be required.

Step 4: Pressure Measurement

Precise determination of your operating pressures is critical. You must specify:

Set Point The primary trip pressure
Proof Pressure Max expected pressure
Burst Pressure Pressure to rupture sensor

Pro Tip: Always specify the mounting orientation (Vertical vs. Horizontal). In very low-pressure switches, the weight of the diaphragm itself can change the setpoint if the orientation is altered.

Supplier Evaluation Checklist

When selecting an OEM partner, look for these core capabilities:

  • Vertical Integration: Do they build from raw materials or just package components?
  • Design Expertise: Are they co-designers capable of rapid prototyping and 3D modeling?
  • Approvals: Do they carry UL, CSA, or industry-specific recognitions like the American Gas Association?
  • Track Record: Ask for performance ratings from major OEM customers.

Ready to specify your switch?

Talk to an Application Engineer